TYW1 series of intelligent type air circuit breaker ( hereinafter referred to as the circuit breaker ), the circuit breaker is applicable to the exchange of 50Hz, rated voltage 400V, 690V, rated current 6300A and below the power distribution network, to the distribution of power and protecting the circuit, preventing power equipment from overload, short circuit, overvoltage, single-phase grounding fault hazard. Circuit breaker protection with intelligent, selective protection range and precision, can improve the reliability of power supply.
Rated current of 630A-6300A;
With 3 pole and 4 pole;
With isolation function;
A variety of intelligent release, providing different functions;
The implementation of IEC60947-2, GB14048.2-2001 standard;
Short circuit breaking energy 80KA-100KA ( effective value);
Drawer type and fixed type;
High breaking capacity, zero flashover;
Be motivated line or line;
Normal working conditions and installation conditions
Ambient air temperature is -5 ℃-40℃, and the mean value of 24h is less than +35℃( with the exception of special order );
The location of the installation elevation not exceeding 2000m;
The installation place of air relative humidity on the highest temperature of +40 ℃when not more than 50%, at lower temperatures can have higher relative humidity, the humidity monthly average lowest temperature of less than +25℃, the monthly average maximum relative humidity of not more than 90%, and consider due to temperature changes occur on the surface of the product the gel;
Pollution grade 3;
Circuit breaker main circuit and under voltage release coil, power transformers at the primary coil install classⅣ, other auxiliary circuit, control circuit installation category iii;
Circuit breaker according to this manual install requires, breaker vertical inclination of not more than 5º;
Circuit breaker installed in the cabinet body chamber, and an additional frame, protection level of IP40; installing frame and a sealed transparent cover, protection level of IP54.
Structure and function
Overload long-time delay, short circuit short-time delay short circuit, instantaneous, single-phase grounding protection function;
A self-test function: overheat protection, microcomputer automatic diagnosis;
Fault memory: fault current, time value, phase sequence memory;
Display function: current setting, action current display; test function;
Optional function
Load monitoring;
Line diagnostic function;
The RS485 serial communication interface;
Function table;
MCR through breaking and the tripping function;
Effects of harmonic coefficient display function.
Brief introduction of structure
Circuit breaker has the advantages of compact structure, small size and other characteristics. Circuit breaker main body is composed of an insulating casing, the contact breaker, operating mechanism, electric energy storage mechanism and other components. Fixed breaker is composed of a main body and mounting plate; drawer type circuit breaker is composed of a main body and the drawer seat, the drawer seat rails can drive circuit breaker body to pull into pull, it has three working positions: " connected ", " test ", " separation ", position changes through the handle moved to achieve. The three position is directed through the drawer bottom base white pointer display.
When in the " connected " position, the main circuit and the two circuit are connected; when in the " test " position, only the two loop is switched on, the main loop is disconnected, this location can be some necessary test; when in the " separation " position, the main loop and two loop disconnects. |
|
 |